これは、こちらの記事の下書きです
http://www.e-agency.co.jp/column/20121107.html
使用したサーバ
http://server.sakura.ad.jp/dedicated/expressg2.html
さくらの専用サーバ エクスプレスG2シリーズ
Fujitsu RX100 S7 Xeon 4Core SATA + ioDrive 320GB Memory 32GB
ioDriveの接続とライブラリの確認
ioDriveの接続を確認
# lspci | grep -i fusion
01:00.0 Mass storage controller: Fusion-io ioDimm3 (rev 01)
ioDriveのRPMパッケージを確認
# rpm -qa | grep "iomemory"
iomemory-vsl-config-2.6.32-220.el6.x86_64-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-source-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-config-2.6.32-279.9.1.el6.x86_64-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-2.6.32-220.el6.x86_64-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-2.6.32-279.9.1.el6.x86_64-2.3.10.110-1.0.el6.x86_64
# rpm -qa | grep "fio"
fio-util-2.3.10.110-1.0.el6.x86_64
fio-firmware-107053-1.0.noarch
fio-common-2.3.10.110-1.0.el6.x86_64
libfio-2.3.10.110-1.0.el6.x86_64
fio-sysvinit-2.3.10.110-1.0.el6.x86_64
ioDriveのステータスを確認
# fio-status -a
Found 1 ioDrive in this system
Fusion-io driver version: 2.3.10 build 110
Adapter: ioDrive
HP 320GB MLC PCIe ioDrive for ProLiant Servers, Product Number:600279-B21 SN:484653
Low-Profile ioDIMM Adapter, PN:00119200008, Mfr:003, Date:20120507
External Power: NOT connected
Powerloss protection: available
PCIE Bus voltage: avg 12.10V, min 12.06V, max 12.11V
PCIE Bus current: avg 0.43A, max 0.99A
PCIE Bus power: avg 5.26W, max 11.96W
PCIE Power limit threshold: 24.75W
PCIE slot available power: 75.00W
Sufficient power available: Unknown
PCIE negotiated link: 4 lanes at 2.50 Gbits/sec each, 1000 MBytes/sec total
Connected ioDimm module:
fct0: HP 320GB MLC PCIe ioDrive for ProLiant Servers, Product Number:600279-B21 SN:488443
fct0 Attached as 'fioa' (block device)
HP 320GB MLC PCIe ioDrive for ProLiant Servers, Product Number:600279-B21 SN:488443
HP ioDIMM 320GB, PN:00309800503, Mfr:003, Date:20120507
Powerloss protection: protected
PCI:01:00.0
Vendor:1aed, Device:1005, Sub vendor:103c, Sub device:178c
Firmware v5.0.7, rev 107053
320.00 GBytes block device size, 406 GBytes physical device size
Format: block, v300, 625,001,920 sectors, 512 bytes per sector
Error correction: 39 bits per 960 bytes
FPGA ID:0 Format UID:0000000773fb013303bb0049dcb8dc00
PCIE slot available power: 75.00W
Sufficient power available: Unknown
PCIE negotiated link: 4 lanes at 2.50 Gbits/sec each, 1000 MBytes/sec total
Internal temperature: 66.0 degC, max 67.9 degC
Board temperature: 54 degC
Internal voltage: avg 0.993V, max 0.996V
Aux voltage: avg 2.470V, max 2.473V
Media status: Healthy; Reserves: 100.00%, warn at 10.00%
Lifetime data volumes:
Physical bytes written: 1,382,385,168
Physical bytes read : 7,432,989,232
RAM usage:
Current: 108,025,856 bytes
Peak : 108,025,856 bytes
ioDriveのパーティションを設定
パーティションを確認。
# /sbin/fdisk -l
Disk /dev/fioa: 320.0 GB, 320000983040 bytes
255 heads, 63 sectors/track, 38904 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 32768 bytes
Disk identifier: 0x00000000
Disk /dev/sda: 999.7 GB, 999653638144 bytes
255 heads, 63 sectors/track, 121534 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x0003365b
Device Boot Start End Blocks Id System
/dev/sda1 * 1 32 256000 83 Linux
Partition 1 does not end on cylinder boundary.
/dev/sda2 32 1052 8192000 82 Linux swap / Solaris
/dev/sda3 1052 121535 967775232 83 Linux
ディスクのパーティションを設定します。
# fdisk /dev/fioa
Device contains neither a valid DOS partition table, nor Sun, SGI or OSF disklabel
Building a new DOS disklabel with disk identifier 0x2ee10d3c.
Changes will remain in memory only, until you decide to write them.
After that, of course, the previous content won't be recoverable.
Warning: invalid flag 0x0000 of partition table 4 will be corrected by w(rite)
WARNING: DOS-compatible mode is deprecated. It's strongly recommended to
switch off the mode (command 'c') and change display units to
sectors (command 'u').
Command (m for help): [n]
Command action
e extended
p primary partition (1-4)
[p]
Partition number (1-4): [1]
First cylinder (1-38904, default 1): [Enter]
Using default value 1
Last cylinder, +cylinders or +size{K,M,G} (1-38904, default 38904): [Enter]
Using default value 38904
Command (m for help): [p]
Disk /dev/fioa: 320.0 GB, 320000983040 bytes
255 heads, 63 sectors/track, 38904 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 32768 bytes
Disk identifier: 0x2ee10d3c
Device Boot Start End Blocks Id System
/dev/fioa1 1 38904 312496348+ 83 Linux
Command (m for help): [w]
The partition table has been altered!
Calling ioctl() to re-read partition table.
Syncing disks.
パーティションブロックの割り当て情報を確認。
# cat /proc/partitions
major minor #blocks name
252 0 312500960 fioa
252 1 312496348 fioa1
8 0 976224256 sda
8 1 256000 sda1
8 2 8192000 sda2
8 3 967775232 sda3
XFSファイルシステムの設定
ioDriveをXFSファイルシステムでフォーマットします。
xfsフォーマットをするのに必要なライブラリをインストール。
# yum install xfsprogs
xfsprogsがインストールされた事を確認。
# yum list | grep xfs
xfsprogs.x86_64 3.1.1-7.el6 @base
xfsdump.x86_64 3.0.4-2.el6 base
xfsprogs.i686 3.1.1-7.el6 base
xfsprogs-devel.i686 3.1.1-7.el6 base
xfsprogs-devel.x86_64 3.1.1-7.el6 base
xfsprogs-qa-devel.i686 3.1.1-7.el6 base
xfsprogs-qa-devel.x86_64 3.1.1-7.el6 base
ファイルシステムxfsでフォーマット。
ブロックサイズを4KBとします。
# /sbin/mkfs.xfs -s size=4096 -b size=4096 /dev/fioa1 -f
meta-data=/dev/fioa1 isize=256 agcount=16, agsize=4882756 blks
= sectsz=4096 attr=2
data = bsize=4096 blocks=78124087, imaxpct=25
= sunit=0 swidth=0 blks
naming =version 2 bsize=4096 ascii-ci=0
log =internal log bsize=4096 blocks=38146, version=2
= sectsz=4096 sunit=1 blks, lazy-count=1
realtime =none extsz=4096 blocks=0, rtextents=0
ioDriveをマウント
# mkdir /fioa
# mount /dev/fioa1 /fioa
ioDriveがXFSファイルシステムでマウントされています。
# df -T
Filesystem Type 1K-blocks Used Available Use% Mounted on
/dev/sda3 ext4 952589244 3222600 900977884 1% /
tmpfs tmpfs 16490208 0 16490208 0% /dev/shm
/dev/sda1 ext4 247919 73226 161893 32% /boot
/dev/fioa1 xfs 312343764 33504 312310260 1% /fioa
サーバ起動時に自動でマウントするように、fstabファイルに追記。
# vi /etc/fstab
/dev/fioa1 /fioa xfs defaults 1 2
I/Oスケジューラの設定
ioDriveドライバのI/Oスケジューラを設定します。
MySQLはI/Oスケジューラをバイパスしてデバイスに直接アクセスする事で、パフォーマンスの向上が見込めます。
Linuxカーネルのモジュールを設定します。
# modprobe iomemory-vsl use_workqueue=0
設定を確認。
# modprobe -c | grep use_workqueue
options iomemory-vsl use_workqueue=0
iomemory-vsl.confに書き込みしておく。
# vi /etc/modprobe.d/iomemory-vsl.conf
options iomemory-vsl use_workqueue=0
参考)
http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c02737596/c02737596.pdf
MySQL5.5(Percona XtraDB)のインストール
MySQL5.5(Percona XtraDB)の64bit versionを使います。
Percona XtraDB(http://www.percona.com/software/percona-server)は、MySQLコンサルティング会社であるPercona社(http://www.percona.com/)が提供しています。
MySQL Community Serverをフォークしたプロダクトです。
通常のMySQLより、マルチコアプロセッサ・I/Oに配慮した設計になっています。
ライセンスはGPLv2で、無料で使えます。
先に、MySQLがインストールされていたら、予めアンインストールしておきましょう。
# yum remove mysql mysql-server mysql-libs php-mysql
Percona公式リポジトリをインストールしたあと、yumコマンドでインストールできます。
# rpm -Uhv http://www.percona.com/downloads/percona-release/percona-release-0.0-1.x86_64.rpm
# yum install Percona-Server-devel-55 Percona-Server-server-55 Percona-Server-client-55
# /usr/bin/mysql_install_db
# /etc/init.d/mysql start
Starting MySQL (Percona Server).. SUCCESS!
# /usr/bin/mysqladmin -u root password 'new-password' #パスワードは便宜設定しましょう
# /usr/bin/mysql -uroot -pnew-password
Welcome to the MySQL monitor. Commands end with ; or \g.
Your MySQL connection id is 4
Server version: 5.5.28-29.1 Percona Server (GPL), Release rel29.1, Revision 335
Copyright (c) 2000, 2012, Oracle and/or its affiliates. All rights reserved.
Oracle is a registered trademark of Oracle Corporation and/or its
affiliates. Other names may be trademarks of their respective
owners.
Type 'help;' or '\h' for help. Type '\c' to clear the current input statement.
mysql>
MySQLが立ち上がりました。
InnoDBエンジンのコメントがPercona-XtraDBとなっていることを確認します。
mysql> SHOW ENGINES \G
*************************** 9. row ***************************
Engine: InnoDB
Support: DEFAULT
Comment: Percona-XtraDB, Supports transactions, row-level locking, and foreign keys
Transactions: YES
XA: YES
Savepoints: YES
9 rows in set (0.00 sec)
起動ログも確認しておきましょう。
# cat /var/log/mysqld.log
121029 14:42:55 mysqld_safe Starting mysqld daemon with databases from /var/lib/mysql
121029 14:42:56 [Note] Plugin 'FEDERATED' is disabled.
121029 14:42:56 InnoDB: The InnoDB memory heap is disabled
121029 14:42:56 InnoDB: Mutexes and rw_locks use GCC atomic builtins
121029 14:42:56 InnoDB: Compressed tables use zlib 1.2.3
121029 14:42:56 InnoDB: Using Linux native AIO
121029 14:42:56 InnoDB: Initializing buffer pool, size = 128.0M
121029 14:42:56 InnoDB: Completed initialization of buffer pool
121029 14:42:56 InnoDB: highest supported file format is Barracuda.
121029 14:42:56 InnoDB: Waiting for the background threads to start
121029 14:42:57 Percona XtraDB (http://www.percona.com) 1.1.8-rel29.1 started; log sequence number 1595675
121029 14:42:57 [Note] Server hostname (bind-address): '0.0.0.0'; port: 3306
121029 14:42:57 [Note] - '0.0.0.0' resolves to '0.0.0.0';
121029 14:42:57 [Note] Server socket created on IP: '0.0.0.0'.
121029 14:42:57 [Note] Event Scheduler: Loaded 0 events
121029 14:42:57 [Note] /usr/sbin/mysqld: ready for connections.
Version: '5.5.28-29.1' socket: '/var/lib/mysql/mysql.sock' port: 3306 Percona Server (GPL), Release rel29.1, Revision 335
phpをインストールするときには、remiレポジトリを使います。
# wget http://rpms.famillecollet.com/enterprise/remi-release-5.rpm
# rpm -Uvh remi-release-5.rpm
# yum --enablerepo=remi install php php-mysql
# php -v
PHP 5.3.18 (cli) (built: Oct 18 2012 08:50:17)
Copyright (c) 1997-2012 The PHP Group
Zend Engine v2.3.0, Copyright (c) 1998-2012 Zend Technologies
my.cnfの設定
ioDrive上にMySQLのデータディレクトリを移動します。
# /etc/init.d/mysql stop
# mv /var/lib/mysql /fioa/
シンボリックリンクを張ります
# ln -s /fioa/mysql /var/lib/mysql
https://github.com/kazeburo/mysetup/blob/master/mysql/my55.cnf
kazeburoさんがgithubで公開されているmy.cnfファイルをベースに設定してきます。
# git clone https://github.com/kazeburo/mysetup.git
# cp /etc/my.cnf /etc/my.cnf.org
# cp mysetup/mysql/my55.cnf /etc/my.cnf
# vi /etc/my.cnf
変更した項目
# サーバID
server-id = 1
# 控えめに搭載メモリ32GBの約70%とします
innodb_buffer_pool_size = 20G
# DiskのIO/secを指定します
innodb_io_capacity = 10000
# CPUのスレッド数を無制限にします
# 参考 innodb_thread_concurrencyとか計測してみました http://www.inter-office.co.jp/contents/122/
innodb_thread_concurrency = 0
# データのflushのタイミングを改善して、I/Oバーストを解消します
# 参考 MySQL Conference&Expo 2010に行ってきました http://engineer.dena.jp/2010/06/mysql-conferenceexpo-2010.html
innodb_adaptive_flushing = 1
# I/Oの速度を0.1秒間隔に保ちます
# 参考 variable innodb_adaptive_flushing_method http://www.percona.com/doc/percona-server/5.5/scalability/innodb_io_55.html#innodb_adaptive_flushing_method
innodb_adaptive_flushing_method = keep_average
# ioDraiveはランダムアクセスのコストがないため、バッファプール内に保留されたダーティページを纏めてテーブルスペースへ書き込む必要がありません。
# 設定をオフにしてパフォーマンスを発揮させます。
innodb_flush_neighbor_pages = 0
MySQLをリスタートします。
innodb_log_file_sizeの値が変わっていますので、ib_logfile0とib_logfile1を退避しておきます。
# /etc/init.d/mysql stop
# mv /var/lib/mysql/ib_logfile0 /tmp
# mv /var/lib/mysql/ib_logfile1 /tmp
# /etc/init.d/mysql start
ログの確認
# tail -f /var/lib/mysql/*.err
MySQLのベンチマーク
MySQLベンチマークツールのtpcc-mysqlを使ってテストデータを挿入します。
tpcc-mysqlをインストール。
# cd /usr/share/
# rpm -Uvh http://dl.fedoraproject.org/pub/epel/5/x86_64/epel-release-5-4.noarch.rpm
# yum --enablerepo=epel install bzr
# bzr branch lp:~percona-dev/perconatools/tpcc-mysql
# cd tpcc-mysql/src
# make all
# cd ..; ls -l
データベースの設定をインポート。
# cd /usr/share/tpcc-mysql
# mysqladmin -uroot -pnew-password create tpcc
# mysql -uroot -pnew-password tpcc < create_table.sql
# mysql -uroot -pnew-password tpcc < add_fkey_idx.sql
テストデータを挿入。
tpcc_loadにはwarehouse(倉庫)というパラメータで挿入するデータ量を決めます。
1 warehouse = 約75MBです。
# ./tpcc_load -h
*************************************
*** ###easy### TPC-C Data Loader ***
*************************************
usage: tpcc_load [server] [DB] [user] [pass] [warehouse]
OR
tpcc_load [server] [DB] [user] [pass] [warehouse] [part] [min_wh] [max_wh]
* [part]: 1=ITEMS 2=WAREHOUSE 3=CUSTOMER 4=ORDERS
# time ./tpcc_load localhost tpcc root 'new-password' 400
挿入完了まで5時間ほどかかりました。
データベースのサイズを見てみましょう。
mysql> SELECT SUM(data_length)/1024/1024 AS total_db_data_in_MB FROM information_schema.tables WHERE table_schema = 'tpcc';
+---------------------+
| total_db_data_in_MB |
+---------------------+
| 30628.68750000 |
+---------------------+
1 row in set (0.02 sec)
30GBのテストデータが準備できました。
このサーバのメモリ量と比べるときついサイズです。
ベンチマークを走らせる前に、テストデータのバックアップをしておきます。
ベンチマークスクリプトはテストデータを更新するためです。
今回は、MySQLバックアップツールのXtraBackup(http://www.submit.ne.jp/1211#1)を使いました。
バックアップ
# time /usr/bin/innobackupex --user root --password pnew-password --slave-info /tmp/xtrabackup/
# time /usr/bin/innobackupex --user root --password pnew-password --apply-log /tmp/xtrabackup/2012-11-02_16-33-27
リストア
# time /usr/bin/innobackupex --copy-back /tmp/xtrabackup/2012-11-02_16-33-27
それでは、ベンチマークを開始しましょう。
warehouseの数を100、同時接続数を10、測定を開始するまでの助走時間を60秒、測定時間を600秒とします。
# ./tpcc_start -h
***************************************
*** ###easy### TPC-C Load Generator ***
***************************************
./tpcc_start: option requires an argument -- 'h'
Usage: tpcc_start -h server_host -P port -d database_name -u mysql_user -p mysql_password -w warehouses -c connections -r warmup_time -l running_time -i report_interval -f report_file -t trx_file
# time ./tpcc_start -h localhost -d tpcc -u root -p 'new-password' -w 400 -c 10 -r 60 -l 600
測定終了まで
topやvmstat 1を眺めて待ちましょう。
TpmCは1分間に処理できるトランザクションの数です。
比較して数値が大きいほど、性能が高い事を示します。
・ファイルシステム XFS フル設定
----------------------------------------------
<TpmC>
29288.500 TpmC
real 11m0.032s
user 3m18.081s
sys 2m50.399s
----------------------------------------------
・ファイルシステム XFS kazeburoさんのmy.cnfに、server-idとinnodb_buffer_pool_size = 20Gを設定したのみのmy.cnf
----------------------------------------------
<TpmC>
25305.900 TpmC
real 11m0.083s
user 2m50.603s
sys 2m25.939s
----------------------------------------------
・ファイルシステム ext4 フル設定
----------------------------------------------
<TpmC>
27609.500 TpmC
real 11m0.052s
user 3m3.894s
sys 2m34.845s
----------------------------------------------
・ファイルシステム ext4 kazeburoさんのmy.cnfに、server-idとinnodb_buffer_pool_size = 20Gを設定したのみのmy.cnf
----------------------------------------------
<TpmC>
27358.000 TpmC
real 11m0.276s
user 3m5.723s
sys 2m37.755s
----------------------------------------------
まとめ
試行回数やパラメータ設定が少なくて、ちょっとベンチマークとしてはいけていないのですが、、、、
それぞれ、大きな差は有りませんでした。
my.cnfの設定はkazeburoさんのmy.cnfにserver-idとinnodb_buffer_pool_sizeを設定したのみの物でも十分にいけると思います。
勿論、実運用へ向けたチューニングとして、実際の挙動にできるだけ近いベンチマークを行う事が望ましいです。
次回は、もう少し細かくベンチマークを取っていきたいですね。
参考資料
http://www.percona.com/files/presentations/percona-live/nyc-2011/PerconaLiveNYC2011-Optimizing-MySQL-for-Solid-State-Storage.pdf
Optimizing MySQL for Solid State Storage
http://blog.father.gedow.net/2012/08/28/iodrive-mysql-event/
第2回 ioDrive+MySQL勉強会 発表資料
http://d.hatena.ne.jp/rx7/20101015/p1
DeNA松信さんの「MySQL環境におけるFusion-io検証結果とDeNAにおける活用価値」セッションメモ
http://www.percona.com/about-us/mysql-white-paper/virident-flashmax-m1400-mysql-tpcc-mysql-report/
Virident FlashMAX M1400 MySQL - tpcc-mysql report
http://www.percona.com/live/london-2011/session/tuning-for-speed-percona-server-and-fusion-io/
Tuning For Speed - Percona Server and Fusion-io
http://www.percona.com/files/white-papers/virident-mlc-tpcc.pdf
Virident FlashMAX M1400 MySQL - Tpcc-Mysql Report
http://blog.nomadscafe.jp/2012/10/mysql-mycnf-github.html
MySQLの設定ファイル my.cnf をgithubにて公開しました & チューニングポイントの紹介
http://www.fusionio.com/blog/mysql-acceleration-through-new-flash-storage-api-primitives/
MySQL Acceleration Through New Flash Storage API Primitives
http://d.hatena.ne.jp/sh2/20090212
tpcc-mysqlによるMySQLのベンチマーク
http://www.e-agency.co.jp/column/20121107.html
使用したサーバ
http://server.sakura.ad.jp/dedicated/expressg2.html
さくらの専用サーバ エクスプレスG2シリーズ
Fujitsu RX100 S7 Xeon 4Core SATA + ioDrive 320GB Memory 32GB
ioDriveの接続とライブラリの確認
ioDriveの接続を確認
# lspci | grep -i fusion
01:00.0 Mass storage controller: Fusion-io ioDimm3 (rev 01)
ioDriveのRPMパッケージを確認
# rpm -qa | grep "iomemory"
iomemory-vsl-config-2.6.32-220.el6.x86_64-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-source-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-config-2.6.32-279.9.1.el6.x86_64-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-2.6.32-220.el6.x86_64-2.3.10.110-1.0.el6.x86_64
iomemory-vsl-2.6.32-279.9.1.el6.x86_64-2.3.10.110-1.0.el6.x86_64
# rpm -qa | grep "fio"
fio-util-2.3.10.110-1.0.el6.x86_64
fio-firmware-107053-1.0.noarch
fio-common-2.3.10.110-1.0.el6.x86_64
libfio-2.3.10.110-1.0.el6.x86_64
fio-sysvinit-2.3.10.110-1.0.el6.x86_64
ioDriveのステータスを確認
# fio-status -a
Found 1 ioDrive in this system
Fusion-io driver version: 2.3.10 build 110
Adapter: ioDrive
HP 320GB MLC PCIe ioDrive for ProLiant Servers, Product Number:600279-B21 SN:484653
Low-Profile ioDIMM Adapter, PN:00119200008, Mfr:003, Date:20120507
External Power: NOT connected
Powerloss protection: available
PCIE Bus voltage: avg 12.10V, min 12.06V, max 12.11V
PCIE Bus current: avg 0.43A, max 0.99A
PCIE Bus power: avg 5.26W, max 11.96W
PCIE Power limit threshold: 24.75W
PCIE slot available power: 75.00W
Sufficient power available: Unknown
PCIE negotiated link: 4 lanes at 2.50 Gbits/sec each, 1000 MBytes/sec total
Connected ioDimm module:
fct0: HP 320GB MLC PCIe ioDrive for ProLiant Servers, Product Number:600279-B21 SN:488443
fct0 Attached as 'fioa' (block device)
HP 320GB MLC PCIe ioDrive for ProLiant Servers, Product Number:600279-B21 SN:488443
HP ioDIMM 320GB, PN:00309800503, Mfr:003, Date:20120507
Powerloss protection: protected
PCI:01:00.0
Vendor:1aed, Device:1005, Sub vendor:103c, Sub device:178c
Firmware v5.0.7, rev 107053
320.00 GBytes block device size, 406 GBytes physical device size
Format: block, v300, 625,001,920 sectors, 512 bytes per sector
Error correction: 39 bits per 960 bytes
FPGA ID:0 Format UID:0000000773fb013303bb0049dcb8dc00
PCIE slot available power: 75.00W
Sufficient power available: Unknown
PCIE negotiated link: 4 lanes at 2.50 Gbits/sec each, 1000 MBytes/sec total
Internal temperature: 66.0 degC, max 67.9 degC
Board temperature: 54 degC
Internal voltage: avg 0.993V, max 0.996V
Aux voltage: avg 2.470V, max 2.473V
Media status: Healthy; Reserves: 100.00%, warn at 10.00%
Lifetime data volumes:
Physical bytes written: 1,382,385,168
Physical bytes read : 7,432,989,232
RAM usage:
Current: 108,025,856 bytes
Peak : 108,025,856 bytes
ioDriveのパーティションを設定
パーティションを確認。
# /sbin/fdisk -l
Disk /dev/fioa: 320.0 GB, 320000983040 bytes
255 heads, 63 sectors/track, 38904 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 32768 bytes
Disk identifier: 0x00000000
Disk /dev/sda: 999.7 GB, 999653638144 bytes
255 heads, 63 sectors/track, 121534 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disk identifier: 0x0003365b
Device Boot Start End Blocks Id System
/dev/sda1 * 1 32 256000 83 Linux
Partition 1 does not end on cylinder boundary.
/dev/sda2 32 1052 8192000 82 Linux swap / Solaris
/dev/sda3 1052 121535 967775232 83 Linux
ディスクのパーティションを設定します。
# fdisk /dev/fioa
Device contains neither a valid DOS partition table, nor Sun, SGI or OSF disklabel
Building a new DOS disklabel with disk identifier 0x2ee10d3c.
Changes will remain in memory only, until you decide to write them.
After that, of course, the previous content won't be recoverable.
Warning: invalid flag 0x0000 of partition table 4 will be corrected by w(rite)
WARNING: DOS-compatible mode is deprecated. It's strongly recommended to
switch off the mode (command 'c') and change display units to
sectors (command 'u').
Command (m for help): [n]
Command action
e extended
p primary partition (1-4)
[p]
Partition number (1-4): [1]
First cylinder (1-38904, default 1): [Enter]
Using default value 1
Last cylinder, +cylinders or +size{K,M,G} (1-38904, default 38904): [Enter]
Using default value 38904
Command (m for help): [p]
Disk /dev/fioa: 320.0 GB, 320000983040 bytes
255 heads, 63 sectors/track, 38904 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 32768 bytes
Disk identifier: 0x2ee10d3c
Device Boot Start End Blocks Id System
/dev/fioa1 1 38904 312496348+ 83 Linux
Command (m for help): [w]
The partition table has been altered!
Calling ioctl() to re-read partition table.
Syncing disks.
パーティションブロックの割り当て情報を確認。
# cat /proc/partitions
major minor #blocks name
252 0 312500960 fioa
252 1 312496348 fioa1
8 0 976224256 sda
8 1 256000 sda1
8 2 8192000 sda2
8 3 967775232 sda3
XFSファイルシステムの設定
ioDriveをXFSファイルシステムでフォーマットします。
ファイルシステムの違いDeNA松信さんの「MySQL環境におけるFusion-io検証結果とDeNAにおける活用価値」セッションメモ(http://d.hatena.ne.jp/rx7/20101015/p1)
ext3は同一ファイルへの書き込みが、同時に1スレッドしかできない(ext4も同様)
xfsはrawデバイスに近い並列性(複数スレッドでの同時書き込み可)
Fusion-ioで使うならXFS
xfsフォーマットをするのに必要なライブラリをインストール。
# yum install xfsprogs
xfsprogsがインストールされた事を確認。
# yum list | grep xfs
xfsprogs.x86_64 3.1.1-7.el6 @base
xfsdump.x86_64 3.0.4-2.el6 base
xfsprogs.i686 3.1.1-7.el6 base
xfsprogs-devel.i686 3.1.1-7.el6 base
xfsprogs-devel.x86_64 3.1.1-7.el6 base
xfsprogs-qa-devel.i686 3.1.1-7.el6 base
xfsprogs-qa-devel.x86_64 3.1.1-7.el6 base
ファイルシステムxfsでフォーマット。
ブロックサイズを4KBとします。
MySQL+ioDriveFusion-io ioDriveの検討資料~運用設定編~(http://blog.father.gedow.net/2012/08/06/fusion-io-iodrive-operaton-configuration/)
XFSは bs=4K 、InnoDBは bs=16K、トランザクションログは 512K とポイントは色々ありますが、MySQL+ioDriveとしては 4Kbyteが最も良好な性能を記録しているため、4Kbyteでフォーマットすることがよさそうです。
# /sbin/mkfs.xfs -s size=4096 -b size=4096 /dev/fioa1 -f
meta-data=/dev/fioa1 isize=256 agcount=16, agsize=4882756 blks
= sectsz=4096 attr=2
data = bsize=4096 blocks=78124087, imaxpct=25
= sunit=0 swidth=0 blks
naming =version 2 bsize=4096 ascii-ci=0
log =internal log bsize=4096 blocks=38146, version=2
= sectsz=4096 sunit=1 blks, lazy-count=1
realtime =none extsz=4096 blocks=0, rtextents=0
ioDriveをマウント
# mkdir /fioa
# mount /dev/fioa1 /fioa
ioDriveがXFSファイルシステムでマウントされています。
# df -T
Filesystem Type 1K-blocks Used Available Use% Mounted on
/dev/sda3 ext4 952589244 3222600 900977884 1% /
tmpfs tmpfs 16490208 0 16490208 0% /dev/shm
/dev/sda1 ext4 247919 73226 161893 32% /boot
/dev/fioa1 xfs 312343764 33504 312310260 1% /fioa
サーバ起動時に自動でマウントするように、fstabファイルに追記。
# vi /etc/fstab
/dev/fioa1 /fioa xfs defaults 1 2
I/Oスケジューラの設定
ioDriveドライバのI/Oスケジューラを設定します。
MySQLはI/Oスケジューラをバイパスしてデバイスに直接アクセスする事で、パフォーマンスの向上が見込めます。
I/O SchedulersTuning For Speed: Percona Server and Fusion-io(http://www.percona.com/files/presentations/percona-live/nyc-2011/PerconaLiveNYC2011-Tuning-For-Speed-Percona-Server-and-Fusion-io.pdf)
- Default with Fusion-io is NOOP
- Merges requests but does not optimize for rotational devices
- For MySQL, submitting requests directly to the device have shown performance improvements. use_workqueue=0
Linuxカーネルのモジュールを設定します。
# modprobe iomemory-vsl use_workqueue=0
設定を確認。
# modprobe -c | grep use_workqueue
options iomemory-vsl use_workqueue=0
iomemory-vsl.confに書き込みしておく。
# vi /etc/modprobe.d/iomemory-vsl.conf
options iomemory-vsl use_workqueue=0
参考)
http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c02737596/c02737596.pdf
The following table describes the module parameters you can set by editing the
/usr/modprobe.d/iomemory-vsl.conf file and changing the values.
/etc/modprobe.d/iomemory-vsl.conf
use_workqueue 3 (1 or 3) Linux only:
3 = Use standard OS I/O elevators
0 = bypass
One-time configuration
The IO Accelerator driver options can be set when the driver is installed on the command line of either
insmod or modprobe. For example, set the auto_attach driver option to 0:
$ modprobe iomemory-vsl auto-attach=0
This option takes effect only for this load of this driver. This option is not set for subsequent calls to modprobe
or insmod.
Persistent configuration
To maintain a persistent setting for an option, add the option to the
/etc/modprobe.d/iomemory-vsl.conf file or a similar file. To prevent the IO Accelerator from
auto-attaching, add the following line to the iomemory-vsl.conf file:
options iomemory-vsl auto_attach=0
The driver option then takes effect for every subsequent driver load, as well as on autoload of the driver
during boot time.
MySQL5.5(Percona XtraDB)のインストール
MySQL5.5(Percona XtraDB)の64bit versionを使います。
Percona XtraDB(http://www.percona.com/software/percona-server)は、MySQLコンサルティング会社であるPercona社(http://www.percona.com/)が提供しています。
MySQL Community Serverをフォークしたプロダクトです。
通常のMySQLより、マルチコアプロセッサ・I/Oに配慮した設計になっています。
ライセンスはGPLv2で、無料で使えます。
先に、MySQLがインストールされていたら、予めアンインストールしておきましょう。
# yum remove mysql mysql-server mysql-libs php-mysql
Percona公式リポジトリをインストールしたあと、yumコマンドでインストールできます。
# rpm -Uhv http://www.percona.com/downloads/percona-release/percona-release-0.0-1.x86_64.rpm
# yum install Percona-Server-devel-55 Percona-Server-server-55 Percona-Server-client-55
# /usr/bin/mysql_install_db
# /etc/init.d/mysql start
Starting MySQL (Percona Server).. SUCCESS!
# /usr/bin/mysqladmin -u root password 'new-password' #パスワードは便宜設定しましょう
# /usr/bin/mysql -uroot -pnew-password
Welcome to the MySQL monitor. Commands end with ; or \g.
Your MySQL connection id is 4
Server version: 5.5.28-29.1 Percona Server (GPL), Release rel29.1, Revision 335
Copyright (c) 2000, 2012, Oracle and/or its affiliates. All rights reserved.
Oracle is a registered trademark of Oracle Corporation and/or its
affiliates. Other names may be trademarks of their respective
owners.
Type 'help;' or '\h' for help. Type '\c' to clear the current input statement.
mysql>
MySQLが立ち上がりました。
InnoDBエンジンのコメントがPercona-XtraDBとなっていることを確認します。
mysql> SHOW ENGINES \G
*************************** 9. row ***************************
Engine: InnoDB
Support: DEFAULT
Comment: Percona-XtraDB, Supports transactions, row-level locking, and foreign keys
Transactions: YES
XA: YES
Savepoints: YES
9 rows in set (0.00 sec)
起動ログも確認しておきましょう。
# cat /var/log/mysqld.log
121029 14:42:55 mysqld_safe Starting mysqld daemon with databases from /var/lib/mysql
121029 14:42:56 [Note] Plugin 'FEDERATED' is disabled.
121029 14:42:56 InnoDB: The InnoDB memory heap is disabled
121029 14:42:56 InnoDB: Mutexes and rw_locks use GCC atomic builtins
121029 14:42:56 InnoDB: Compressed tables use zlib 1.2.3
121029 14:42:56 InnoDB: Using Linux native AIO
121029 14:42:56 InnoDB: Initializing buffer pool, size = 128.0M
121029 14:42:56 InnoDB: Completed initialization of buffer pool
121029 14:42:56 InnoDB: highest supported file format is Barracuda.
121029 14:42:56 InnoDB: Waiting for the background threads to start
121029 14:42:57 Percona XtraDB (http://www.percona.com) 1.1.8-rel29.1 started; log sequence number 1595675
121029 14:42:57 [Note] Server hostname (bind-address): '0.0.0.0'; port: 3306
121029 14:42:57 [Note] - '0.0.0.0' resolves to '0.0.0.0';
121029 14:42:57 [Note] Server socket created on IP: '0.0.0.0'.
121029 14:42:57 [Note] Event Scheduler: Loaded 0 events
121029 14:42:57 [Note] /usr/sbin/mysqld: ready for connections.
Version: '5.5.28-29.1' socket: '/var/lib/mysql/mysql.sock' port: 3306 Percona Server (GPL), Release rel29.1, Revision 335
phpをインストールするときには、remiレポジトリを使います。
# wget http://rpms.famillecollet.com/enterprise/remi-release-5.rpm
# rpm -Uvh remi-release-5.rpm
# yum --enablerepo=remi install php php-mysql
# php -v
PHP 5.3.18 (cli) (built: Oct 18 2012 08:50:17)
Copyright (c) 1997-2012 The PHP Group
Zend Engine v2.3.0, Copyright (c) 1998-2012 Zend Technologies
my.cnfの設定
ioDrive上にMySQLのデータディレクトリを移動します。
# /etc/init.d/mysql stop
# mv /var/lib/mysql /fioa/
シンボリックリンクを張ります
# ln -s /fioa/mysql /var/lib/mysql
https://github.com/kazeburo/mysetup/blob/master/mysql/my55.cnf
kazeburoさんがgithubで公開されているmy.cnfファイルをベースに設定してきます。
# git clone https://github.com/kazeburo/mysetup.git
# cp /etc/my.cnf /etc/my.cnf.org
# cp mysetup/mysql/my55.cnf /etc/my.cnf
# vi /etc/my.cnf
変更した項目
# サーバID
server-id = 1
# 控えめに搭載メモリ32GBの約70%とします
innodb_buffer_pool_size = 20G
# DiskのIO/secを指定します
innodb_io_capacity = 10000
# CPUのスレッド数を無制限にします
# 参考 innodb_thread_concurrencyとか計測してみました http://www.inter-office.co.jp/contents/122/
innodb_thread_concurrency = 0
# データのflushのタイミングを改善して、I/Oバーストを解消します
# 参考 MySQL Conference&Expo 2010に行ってきました http://engineer.dena.jp/2010/06/mysql-conferenceexpo-2010.html
innodb_adaptive_flushing = 1
# I/Oの速度を0.1秒間隔に保ちます
# 参考 variable innodb_adaptive_flushing_method http://www.percona.com/doc/percona-server/5.5/scalability/innodb_io_55.html#innodb_adaptive_flushing_method
innodb_adaptive_flushing_method = keep_average
# ioDraiveはランダムアクセスのコストがないため、バッファプール内に保留されたダーティページを纏めてテーブルスペースへ書き込む必要がありません。
# 設定をオフにしてパフォーマンスを発揮させます。
innodb_flush_neighbor_pages = 0
MySQLをリスタートします。
innodb_log_file_sizeの値が変わっていますので、ib_logfile0とib_logfile1を退避しておきます。
# /etc/init.d/mysql stop
# mv /var/lib/mysql/ib_logfile0 /tmp
# mv /var/lib/mysql/ib_logfile1 /tmp
# /etc/init.d/mysql start
ログの確認
# tail -f /var/lib/mysql/*.err
MySQLのベンチマーク
MySQLベンチマークツールのtpcc-mysqlを使ってテストデータを挿入します。
tpcc-mysqlをインストール。
# cd /usr/share/
# rpm -Uvh http://dl.fedoraproject.org/pub/epel/5/x86_64/epel-release-5-4.noarch.rpm
# yum --enablerepo=epel install bzr
# bzr branch lp:~percona-dev/perconatools/tpcc-mysql
# cd tpcc-mysql/src
# make all
# cd ..; ls -l
データベースの設定をインポート。
# cd /usr/share/tpcc-mysql
# mysqladmin -uroot -pnew-password create tpcc
# mysql -uroot -pnew-password tpcc < create_table.sql
# mysql -uroot -pnew-password tpcc < add_fkey_idx.sql
テストデータを挿入。
tpcc_loadにはwarehouse(倉庫)というパラメータで挿入するデータ量を決めます。
1 warehouse = 約75MBです。
# ./tpcc_load -h
*************************************
*** ###easy### TPC-C Data Loader ***
*************************************
usage: tpcc_load [server] [DB] [user] [pass] [warehouse]
OR
tpcc_load [server] [DB] [user] [pass] [warehouse] [part] [min_wh] [max_wh]
* [part]: 1=ITEMS 2=WAREHOUSE 3=CUSTOMER 4=ORDERS
# time ./tpcc_load localhost tpcc root 'new-password' 400
挿入完了まで5時間ほどかかりました。
データベースのサイズを見てみましょう。
mysql> SELECT SUM(data_length)/1024/1024 AS total_db_data_in_MB FROM information_schema.tables WHERE table_schema = 'tpcc';
+---------------------+
| total_db_data_in_MB |
+---------------------+
| 30628.68750000 |
+---------------------+
1 row in set (0.02 sec)
30GBのテストデータが準備できました。
このサーバのメモリ量と比べるときついサイズです。
ベンチマークを走らせる前に、テストデータのバックアップをしておきます。
ベンチマークスクリプトはテストデータを更新するためです。
今回は、MySQLバックアップツールのXtraBackup(http://www.submit.ne.jp/1211#1)を使いました。
バックアップ
# time /usr/bin/innobackupex --user root --password pnew-password --slave-info /tmp/xtrabackup/
# time /usr/bin/innobackupex --user root --password pnew-password --apply-log /tmp/xtrabackup/2012-11-02_16-33-27
リストア
# time /usr/bin/innobackupex --copy-back /tmp/xtrabackup/2012-11-02_16-33-27
それでは、ベンチマークを開始しましょう。
warehouseの数を100、同時接続数を10、測定を開始するまでの助走時間を60秒、測定時間を600秒とします。
# ./tpcc_start -h
***************************************
*** ###easy### TPC-C Load Generator ***
***************************************
./tpcc_start: option requires an argument -- 'h'
Usage: tpcc_start -h server_host -P port -d database_name -u mysql_user -p mysql_password -w warehouses -c connections -r warmup_time -l running_time -i report_interval -f report_file -t trx_file
# time ./tpcc_start -h localhost -d tpcc -u root -p 'new-password' -w 400 -c 10 -r 60 -l 600
測定終了まで
topやvmstat 1を眺めて待ちましょう。
TpmCは1分間に処理できるトランザクションの数です。
比較して数値が大きいほど、性能が高い事を示します。
・ファイルシステム XFS フル設定
----------------------------------------------
<TpmC>
29288.500 TpmC
real 11m0.032s
user 3m18.081s
sys 2m50.399s
----------------------------------------------
・ファイルシステム XFS kazeburoさんのmy.cnfに、server-idとinnodb_buffer_pool_size = 20Gを設定したのみのmy.cnf
----------------------------------------------
<TpmC>
25305.900 TpmC
real 11m0.083s
user 2m50.603s
sys 2m25.939s
----------------------------------------------
・ファイルシステム ext4 フル設定
----------------------------------------------
<TpmC>
27609.500 TpmC
real 11m0.052s
user 3m3.894s
sys 2m34.845s
----------------------------------------------
・ファイルシステム ext4 kazeburoさんのmy.cnfに、server-idとinnodb_buffer_pool_size = 20Gを設定したのみのmy.cnf
----------------------------------------------
<TpmC>
27358.000 TpmC
real 11m0.276s
user 3m5.723s
sys 2m37.755s
----------------------------------------------
まとめ
試行回数やパラメータ設定が少なくて、ちょっとベンチマークとしてはいけていないのですが、、、、
それぞれ、大きな差は有りませんでした。
my.cnfの設定はkazeburoさんのmy.cnfにserver-idとinnodb_buffer_pool_sizeを設定したのみの物でも十分にいけると思います。
勿論、実運用へ向けたチューニングとして、実際の挙動にできるだけ近いベンチマークを行う事が望ましいです。
次回は、もう少し細かくベンチマークを取っていきたいですね。
参考資料
http://www.percona.com/files/presentations/percona-live/nyc-2011/PerconaLiveNYC2011-Optimizing-MySQL-for-Solid-State-Storage.pdf
Optimizing MySQL for Solid State Storage
http://blog.father.gedow.net/2012/08/28/iodrive-mysql-event/
第2回 ioDrive+MySQL勉強会 発表資料
http://d.hatena.ne.jp/rx7/20101015/p1
DeNA松信さんの「MySQL環境におけるFusion-io検証結果とDeNAにおける活用価値」セッションメモ
http://www.percona.com/about-us/mysql-white-paper/virident-flashmax-m1400-mysql-tpcc-mysql-report/
Virident FlashMAX M1400 MySQL - tpcc-mysql report
http://www.percona.com/live/london-2011/session/tuning-for-speed-percona-server-and-fusion-io/
Tuning For Speed - Percona Server and Fusion-io
http://www.percona.com/files/white-papers/virident-mlc-tpcc.pdf
Virident FlashMAX M1400 MySQL - Tpcc-Mysql Report
http://blog.nomadscafe.jp/2012/10/mysql-mycnf-github.html
MySQLの設定ファイル my.cnf をgithubにて公開しました & チューニングポイントの紹介
http://www.fusionio.com/blog/mysql-acceleration-through-new-flash-storage-api-primitives/
MySQL Acceleration Through New Flash Storage API Primitives
http://d.hatena.ne.jp/sh2/20090212
tpcc-mysqlによるMySQLのベンチマーク